NVMe tiering migration

The execution plan for ADR 0009: retire tank's oversized SLOG, build fast as a mirror of the two SN850X, and move 61 VM zvols onto it. This supersedes stages 3 and 4 of the ADR 0008 runbook.

Read this first: the two drives are coupled

nvme0n1p1 is tank's log vdev today. nvme1n1p1 is free. They cannot both join a mirror until the SLOG is retired, so the SLOG removal is a prerequisite of building fast, not a follow-up. ADR 0008 has these in the opposite order and that order is not executable.

Ordering constraints

Nothing below is optional and nothing below reorders safely.

Step 0  ZFS health alerting (#175)        ─┐
Step 1  pbs1 -> pbs2 sync job (#215)       ├─ do these now, this week
                                           │  they are the interim mitigation
Step 2  RMA #193, zpool replace x3        ─┤  blocked on vendor
Step 3  PVE 9 + freenas-proxmox 3.0.0     ─┤  blocked on step 0 and 1
Step 4  remove tank's SLOG                ─┤  irreversible-ish window opens
Step 5  partition both drives, build fast ─┤
Step 6  migrate 61 zvols, set quota       ─┤
Step 7  decide on the 32 GiB SLOG slice   ─┘  blocked on step 6 measurement

CANCELLED: ADR 0008 step 4, the tank mirror rebalance. Step 2 replaces it.
NOT IN SCOPE: moving tank/k8s. Immutable PV paths. Separate change.
Step Blocks on Reversible Lab exposed
0 Alerting nothing n/a, pure addition no
1 PBS sync nothing n/a, pure addition no
2 RMA replace vendor, step 0 per-drive, resilver yes, resilver load on bad drives
3 PVE 9 steps 0, 1 snapshot/rollback per node yes, node reboots
4 Remove SLOG step 3 zpool add tank log yes, sync latency 4-6x worse until step 6 completes
5 Build fast step 4 zpool destroy fast no
6 Migrate zvols step 5 Move Disk back, per VM yes, 2233 snapshots lost irreversibly
7 SLOG slice step 6 zpool remove no

The only irreversible thing in this plan is the snapshot loss in step 6. Everything else can be undone, at a cost. That does not make the rest safe to run casually: see the warning on step 4.

Before anything: record the baseline

"It feels faster" is not a result. Capture this and keep the output.

# NAS
ssh truenas_admin@192.168.1.15 '
  sudo zpool status tank
  sudo zpool list -v -p tank
  sudo zpool iostat -v -l tank 60 2
  sudo zfs list -r -t volume -H -p -o used tank/proxmox_zfs_vms |
    awk "{s+=\$1} END {printf \"%.1f GiB used\n\", s/1073741824}"
  sudo zfs list -r -t snapshot -H -o name tank/proxmox_zfs_vms | wc -l
  awk "/^(size|c|c_max|hits|misses|l2_hdr_size)/ {print \$1, \$3}" \
    /proc/spl/kstat/zfs/arcstats
  sudo dmesg | grep -ciE "COMRESET|hard resetting|failed command"
'

Baseline measured 2026-10-07 at 17:39, 16 days 2 hours of uptime:

Metric Value
tank 14.7 T size, 5.03 T alloc, 9.66 T free, 25% frag, 34% cap, ONLINE, 0 errors
Log vdev write 49 IOPS, 3.70 MiB/s, 88us disk_wait, 92us total_wait
Data vdev write 211 IOPS, 8.78 MiB/s, 346-593us disk_wait, 1-2ms total_wait
ARC size 46.86 GiB, c 48.28 GiB, c_max 61.55 GiB, hit rate 99.08%
l2_hdr_size 0 (L2ARC removed 2026-09-20)
zvols 61, 2785.1 GiB provisioned, 663.8 GiB used, 506.0 GiB referenced
Snapshots 2233, holding 157.8 GiB
ata resets since boot 0
etcd WAL fsync about 74 ms (from ADR 0008, re-measure, this is stale)

Step 0: ZFS pool health alerting

Blocking. Do not skip. Do not reorder.

Three drives dropped off the SATA bus and Prometheus stayed silent (ansible-quasarlab#175). Every step from 2 onward puts load on drives that have failed before. Running those with no alerting is how 2026-09-20 turned a recoverable event into a 4.5 hour wedge and a cold power cycle.

What must exist before step 2:

  • A metric carrying zpool status health per pool, scraped into Prometheus.
  • An alert on anything other than ONLINE, and separately on non-zero read/write/checksum counters.
  • An alert on resilver in progress, so a resilver nobody started is visible.
  • A Discord route that has been tested, not assumed.

Verify the series exists before trusting the rule

This lab has shipped vacuous alert rules before: node_exporter --collector.systemd.unit-include allowlists made rules for unlisted units silently unfirable and hid three real outages. Query the metric in Prometheus and confirm it returns data for tank specifically before believing the rule covers anything.

Rollback point: none needed, pure addition.

Step 1: pbs1 to pbs2 sync job

Blocking. Cheapest risk reduction available.

pbs1 (vm103 on pve) runs PBS 3.4.9 with datastore lab on a 600 G disk on pve's local SSD2, once a day at 10:00 UTC, all VMs, excluding vm9000, --verify-new, retention 1/7/4/3. A restore drill passed: nginx2 restored to a scratch VMID with hostname, kernel, root filesystem, package count and /etc md5 all identical to the live host.

Backups were hourly with retention 24/7/4/3 until 2026-10-15 (ansible-quasarlab#241). The RPO is now 24 hours, not one, which matters in step 6 below: a backup taken "recently" is no longer necessarily within the hour. The schedule is pinned to UTC rather than written as a local time because a cluster backup job is evaluated on every node in that node's local time, and pve is America/Los_Angeles while pve2 is America/New_York.

pbs2 (vm120 on pve2) is staged but empty: qm config 120 confirms scsi0: ssd_1:vm-120-disk-0,size=32G and scsi1: ssd_2:vm-120-disk-0,size=600G, but PBS is not installed and the sync job does not exist.

  1. Merge ansible-quasarlab#215 and install PBS on pbs2.
  2. Create a remote + sync job pulling datastore lab from pbs1.
  3. Run a verify job on pbs2's datastore.
  4. Restore one VM from pbs2, not from pbs1, to a scratch VMID, and diff it the way the nginx2 drill did.

Step 4 is the point of the exercise. A sync job that has never been restored from is a sync job you are guessing about.

Why this is on the critical path and not a nice-to-have

Step 6 irreversibly discards 2233 snapshots. PBS is what replaces them as the recovery mechanism for VM disks. One copy of the replacement, on a 600 G local disk on one node, is thin cover for discarding the other mechanism entirely.

Rollback point: none needed, pure addition.

Step 2: RMA #193, then zpool replace

Blocked on the vendor. Blocked on step 0.

Three drives are RMA-pending, identifiable by serial prefix. Verified mapping as of 2026-10-07:

vdev Member Serial Batch
mirror-0 /dev/sdg1 WD Blue 24230KD00111 good
mirror-0 /dev/sdh1 WD Blue 24230KD00129 good
mirror-1 /dev/sdf1 WD Blue 24230KD00005 good
mirror-1 /dev/sdc1 Inland IB24AK0004S00013 bad
mirror-2 /dev/sda1 Inland IB24AJ0004S00183 good
mirror-2 /dev/sde1 Inland IB24AJ0004S00059 good
mirror-3 /dev/sdd1 Inland IB24AK0004S00064 bad
mirror-3 /dev/sdb1 Inland IB24AK0004S00004 bad

smartctl -i reports only Inland SATA SSD for all five, so the serial prefix is the discriminator: IB24AK is the bad batch, IB24AJ is not.

Identify the physical tray by serial, never by sd letter

sd letters are not stable across boots. On the DXP8800 the LED diskN maps to ataN, which maps to the Nth tray left to right, and not to sd letters. Confirm which tray someone actually pulled from ata link down events in dmesg, not from the letter.

Procedure, one drive at a time:

  1. Confirm zpool status tank is ONLINE with zero errors. If it is not, stop.
  2. zpool replace tank <bad-partuuid> <new-partuuid>.
  3. Watch the resilver to completion. Watch dmesg for COMRESET and hard resetting link throughout.
  4. Confirm ONLINE and zero errors before touching the next drive.

Do mirror-3 first (both members bad), then mirror-1.

replace, not detach-and-attach

zpool replace keeps the old drive in the vdev until the resilver completes, so the vdev never runs degraded. A rebalance by detach then attach runs the resilver on a deliberately degraded vdev, which is precisely the scenario ADR 0008's own consequences section calls "how a pool is lost". This is why ADR 0008 step 4 is cancelled: the RMA dissolves the mirror-3 pairing without ever degrading a vdev, and rebalancing first would mean six resilvers on bad drives instead of three.

Rollback point: a zpool replace can be cancelled mid-resilver with zpool detach of the incoming device. The vdev returns to its prior membership.

Lab exposed: yes. Resilver reads put sustained load on drives whose failure trigger is not established, so "wait for a quiet moment" is not a mitigation. One vdev at a time, alerting live, PBS verified.

Step 3: PVE 9 and freenas-proxmox 3.0.0

Blocked on steps 0 and 1. Blocks step 5.

Both nodes run pve-manager/8.4.21, EOL since 2026-08-31. The ZFS-over-iSCSI plugin is held:

$ apt-mark showhold
freenas-proxmox
$ dpkg -l freenas-proxmox
hi  freenas-proxmox  2.4.0-1  all

2.4.0-1 fails the PVE 8 to 9 dist-upgrade through its dpkg trigger, and per upstream ADR-009 only plugin v3.0.0 loads on PVE 8.4 (api() 11 against APIVER 11).

Why this is sequenced before fast and not after. fast needs a second zfs: storage definition, interpreted by this plugin. Defining it against 2.4.0 means validating the whole migration against a plugin that must then be replaced, and revalidating afterwards. Do the plugin work once, then define fast once.

Order within the step:

  1. Upgrade the plugin to 3.0.0 on PVE 8.4 first, while the existing truenas-iscsi definition is the only one in play. Confirm VMs still start, stop and snapshot.
  2. Then dist-upgrade to PVE 9, one node at a time.

etcd and the node order

2 of 3 etcd members (k8cluster2, k8cluster3) are both on pve2, and their disks are node-local, so they are not clean live migrations. Rebooting pve2 kills the Kubernetes control plane quorum. Upgrade pve first, confirm the cluster is healthy, then pve2.

Live migration between the nodes is impossible regardless (Intel pve against AMD pve2), so every VM relocation here is shutdown-and-start.

Rollback point: per node, a pre-upgrade snapshot or a known-good kernel entry. Keep the old plugin .deb on disk.

Lab exposed: yes, node reboots, control plane quorum on the pve2 reboot.

Step 4: remove tank's SLOG

Blocked on step 3. This opens the exposure window.

# The device: PARTUUID a1bfbe13-bfc0-4e7c-92e4-c28c963225e6 = nvme0n1p1
sudo zpool remove tank a1bfbe13-bfc0-4e7c-92e4-c28c963225e6

This is a pool topology change on an appliance that has wedged

On 2026-09-20 a zpool remove of the cache vdev, pitched in ADR 0008 as "instant, reversible, no migration", aggravated an already-overloaded NAS into a 4.5 hour wedge and forced a cold power cycle.

Removing a log vdev is mechanically a much smaller operation: that removal had 20.6 GiB of l2_hdr_size to tear out of ARC, and a log removal has no ARC work at all. It quiesces the ZIL, flushes outstanding sync writes to the data vdevs, and detaches.

That is not permission to run it casually. "Reversible" and "safe to run right now" are different claims and ADR 0008 collapsed them. Run it in a window, at low load, with alerting live, PBS verified, and zpool iostat -v -l tank 5 open in another pane.

Never run a pool topology change mid-incident.

The exposure this opens

From this moment until the last VM leaves tank in step 6, every guest fsync on tank lands on the SATA mirrors. Measured difference:

With SLOG Without (predicted)
Sync write disk_wait 88us 346-593us
Sync write total_wait 92us 1-2ms

Roughly 4x to 6x worse per sync write, and sync writes now contend with data writes on the same devices. 42% of the bytes reaching tank's data vdevs currently pass through the ZIL first, so this is not a corner case.

The thing that cares most is etcd WAL fsync, baseline about 74 ms, with 2 of 3 members on pve2. Re-measure it immediately after the removal and again after step 6.

Why take this hit rather than avoid it

The alternative ordering is to build fast as a single-device pool on the already-free nvme1n1, migrate everything, then remove the SLOG and attach nvme0n1p2 to make it a mirror. That keeps the 92us sync path for the whole migration.

It also puts every VM disk in the lab on one non-redundant device for the duration of the migration plus the subsequent resilver. That trades a bounded, measurable, reversible performance cost for an unbounded data-loss cost. Take the latency hit.

Rollback point: zpool add tank log a1bfbe13-... restores it in seconds, at any time before step 5 repartitions the drive. After step 5 the partition is gone and this rollback no longer exists, which is why step 5 creates the 32 GiB replacement slices.

Step 5: partition both drives and build fast

Blocked on step 4.

Partition both SN850X identically: a 32 GiB p1 and the remainder as p2. Build the mirror on the p2 pair. Leave both p1 slices unused.

nvme0n1  ->  p1  32 GiB   (unused, reserved for a log vdev)
             p2  ~3.61 TiB -> fast mirror leg
nvme1n1  ->  p1  32 GiB   (unused, reserved)
             p2  ~3.61 TiB -> fast mirror leg

This decision cannot be deferred

You cannot carve a partition off a drive that is already a whole-disk vdev member without destroying the pool. The SLOG role is measurably real, so the option has to be preserved now or not at all. The cost is 64 GiB of 7.3 TiB raw. The cost of skipping it is redoing this entire migration.

ZFS on partitions is already how this box works: boot-pool is nvme2n1p3, and today's SLOG is itself nvme0n1p1, not a whole disk.

Then create the pool with ashift=12 to match the existing vdevs (verified: every tank vdev is ashift: 12), and a proxmox_zfs_vms child with the same properties the current one has: volblocksize/recordsize 16 K, compression=lz4, sync=standard, logbias=latency.

Set a quota, not a refquota

quota on fast/proxmox_zfs_vms = 2.5T

refquota on the parent bounds nothing

tank/proxmox_zfs_vms has refquota=4T and it is vacuous. Verified: the parent reports AVAIL 4.00T while every child zvol reports AVAIL 9.53T, the whole pool's free space. refquota excludes descendants. Proxmox displays it as the storage ceiling anyway.

61 zvols commit 2785.1 GiB thin against 663.8 GiB actually used. On a 3.64 TiB mirror that is 75% committed before a single snapshot, and ZFS degrades past roughly 80%. On tank the overcommit was harmless because 9.66 T was free. On fast it is not.

zvol_enforce_quotas is 1, so a real quota will be honoured. Verify it by reading AVAIL on a child zvol, not on the parent.

Rollback point: zpool destroy fast while it is empty. The p1 slices mean step 4's rollback (zpool add tank log <p1>) is available again from here on.

Step 6: migrate the zvols

Blocked on step 5. Contains the only irreversible action in this plan.

Add the fast storage definition in /etc/pve/storage.cfg, mirroring the existing one but pointing at the new pool. For reference, the current definition:

zfs: truenas-iscsi
    blocksize 16k
    iscsiprovider freenas
    pool tank/proxmox_zfs_vms
    portal 10.10.12.2
    target iqn.2005-10.org.freenas.ctl:proxmox-cluster
    content images
    sparse 1

Then move disks with the PVE Move Disk action, one VM at a time. This is the same technique that rebooted the NAS with zero VM downtime on 2026-09-19; the existing runbook covers the throttle and the etcd cautions and they apply unchanged.

Migration order

Sync-sensitive first, so the workloads that suffer most from step 4's regression spend the least time on the SLOG-less pool:

  1. etcd members. k8cluster2 and k8cluster3 are both on pve2. One at a time, confirming quorum between each.
  2. The Postgres VM, and anything else with a database.
  3. command-center1, noting that its cloud-init drive is on the NAS (#199).
  4. Everything else.
  5. The QDevice VM last, or plan around it: it provides the third corosync vote and it runs on the NAS.

The irreversible part

Move Disk discards snapshots. 2233 of them, holding 157.8 GiB.

Move Disk copies current state only. PVE-level snapshots do not survive it and neither do the hourly TrueNAS periodic snapshots.

This is acceptable now and was not when ADR 0008 was written. Before 2026-10-06 those snapshots were the only recovery mechanism for VM disks. PBS now is: daily at 10:00 UTC, all VMs, --verify-new, 1/7/4/3, with a restore verified against nginx2. Step 1 existing is what makes this step affordable. If step 1 is not done, do not run step 6.

Confirm a current PBS backup for each VM immediately before moving it. With a daily schedule that means triggering the job by hand rather than assuming the hourly run has been past recently: run it from the PVE UI, or pvesh create /nodes/<node>/vzdump --vmid <vmid> --storage pbs-lab --mode snapshot, and wait for the task to report OK.

zfs send -R is not an alternative

It would preserve all 2233 snapshots, but the freenas-proxmox plugin creates the SCST extents through the TrueNAS API. Hand-replicated zvols arrive with no iSCSI target mapping, so PVE cannot attach them. Use Move Disk and accept the loss.

Rollback point: per VM, Move Disk back to truenas-iscsi. The snapshots are already gone by then and do not come back.

Not in scope: tank/k8s

ADR 0008 step 2 moves tank/k8s (45.9 G) alongside the zvols. Do not.

Every Kubernetes PV has the dataset path baked into an immutable field. Verified on Loki's 50 Gi volume:

spec:
  nfs:
    path: /mnt/tank/k8s/monitoring/storage-loki-0
    server: 192.168.1.15

spec.nfs.path is immutable on a PV. Moving the dataset invalidates roughly twenty bound PVs, each needing deletion and recreation with volumeName re-binding, plus a Helm values change for nfs-subdir-external-provisioner's NFS_PATH. Different work, different failure mode (pods stuck mounting), and it should not ride along with a zvol migration. Those PVs also target 192.168.1.15, the 1 G LAN interface, not 10.10.12.2 on the 10 G storage network, so NVMe backing would be partly wasted behind the transport.

Step 7: decide on the 32 GiB SLOG slice

Blocked on step 6, and on measurement.

With the VM disks gone, tank's sync load should collapse to NFS-sync traffic on media, isos, k8s, terraform and files only. Measure it:

sudo zpool iostat -v -l tank 60 5
  • If log-vdev-equivalent sync traffic is negligible, leave the p1 slices unused. tank genuinely does not want a log device any more, and that is when ADR 0008 step 3's conclusion becomes correct, for reasons it did not give.
  • If NFS write latency regressed, zpool add tank log <nvme0n1p1>.

A log slice on a fast mirror member is acceptable

If nvme0n1 then fails, fast goes degraded (survivable, it is a mirror) and tank loses its log (survivable, the pool imports and only in-flight sync writes from a simultaneous crash are at risk). The two pools share a physical device, which is worth knowing, but neither loses data from it.

A single-device log is not the hazard it was before ZFS supported log device removal and pool import without one.

Rollback point: zpool remove tank <p1> at any time.

Also do, independently of all of the above

Cap zfs_arc_max at 48 GiB (51539607552 bytes), in Ansible, not by hand.

zfs_arc_max is 0 today, so c_max is 66,086,522,880 bytes, 61.55 GiB of 62 GiB host RAM. ARC has self-tuned to a 48.28 GiB target and 46.86 GiB actual, so 48 GiB pins it where it already sits and removes only the headroom to balloon and starve SCST, nfsd, middlewared, ix-apps and the QDevice VM.

Do not credit this with fixing anything

The specific RAM pressure that contributed to 2026-09-20 was l2_hdr_size at 20.6 GiB and it is already gone (l2_hdr_size reads 0). arc_no_grow is 0 and evict_skip is 8,161, so ARC is not under pressure today. This is a cheap ceiling against a future workload, not a remedy for an observed problem. High confidence it is harmless, medium confidence it is necessary.

Follow-up

Fill in the validation table in ADR 0009 as each step lands, and leave the unfilled rows visibly unfilled.

ADR 0008 warned against "a plan recorded as though it were an outcome", then had step 1 executed with all three of its predicted outcomes unrecorded and none of them true as written. The warning was right and was not followed.

The row most likely to be skipped is the quota check, and it is the one that has already caught this lab out: read AVAIL on a child zvol, not on the parent.