ADR 0009: What the two SN850X should actually do

Status: Proposed. Supersedes ADR 0008 steps 3 and 4, and amends step 2. Date: 2026-10-07 Measurements taken: 2026-10-07, read-only, against 192.168.1.15, 192.168.1.10 and the Kubernetes API.

The question

The NAS holds two 4 TB WD_BLACK SN850X. One is tank's SLOG, one is idle since the L2ARC was removed on 2026-09-20. The question put to this ADR was open: "maybe a new datastore for something else". ADR 0008 already proposed an answer, but it was written on 2026-09-20, several of its load-bearing facts have changed, and exactly one of its four steps has been executed.

This ADR re-derives the answer from measurements taken today. The short version: ADR 0008's end state is still right, its reasoning for two of the four steps is wrong, and it omits the one constraint that determines the whole ordering.

What changed since ADR 0008

2026-09-20 (ADR 0008) 2026-10-07 (today)
L2ARC 3.4 TB, l2_hdr_size 20.6 GiB, 43% of ARC Gone. l2_size, l2_asize, l2_hdr_size, l2_hits all 0
VM disk backups tank/backups, 158 G of vzdump, on the pool it protects PBS 3.4.9 on pbs1, hourly, all VMs, --verify-new, 24/7/4/3, restore drill passed. tank/backups destroyed (terraform-quasarlab#26)
SLOG assessment "11.5 MiB used of 3.64 TB", "not earning it" Earning it. 49 write IOPS and 3.70 MiB/s sustained at 92us. See Finding 1
ARC hit rate 99.27% 99.08% lifetime, metadata 99.99%
tank health 3 drives had dropped off the bus ONLINE, 0 errors, 0 ata resets in 16 days
PVE 8.4.21, EOL 2026-08-31 Unchanged, still EOL, plugin still held at 2.4.0-1

Two of those changes matter enough to move the decision. PBS existing changes the cost of every destructive step below. The SLOG measurement reverses ADR 0008 step 3.

The constraint ADR 0008 never states

nvme0n1p1 is tank's log vdev right now (blkid reports LABEL="tank" TYPE="zfs_member", and its PARTUUID a1bfbe13-bfc0-4e7c-92e4-c28c963225e6 is the device under logs in zpool status). nvme1n1p1 is a member of nothing: zdb -l still finds a stale L2ARC device header on it carrying pool_guid 7043569411961946042 (which is tank) and state: 4, but blkid reports no pool label.

So the two drives cannot both join a new mirror until the SLOG is retired. ADR 0008 lists "create fast" as step 2 and "retire the SLOG" as step 3, in that order, which is not executable. The steps are coupled and the dependency runs the other way. Everything in the runbook follows from this.

Finding 1: the SLOG is earning its place

ADR 0008 retired the SLOG on the grounds that it held 11.5 MiB of a 3.64 TB device. That is a measurement of allocation, and it says nothing about utility. ZIL blocks are freed on every txg commit, so near-zero allocation is the correct and expected steady state for a healthy SLOG. A SLOG that had filled up would be the pathology.

The metrics that do measure utility are IOPS, bandwidth and latency. All three say it is working.

Measurement Log vdev tank data vdevs Source
Write IOPS, since boot (16d) 49/s 211/s across 4 mirrors zpool iostat -v tank
Write bandwidth, since boot 3.70 MiB/s 8.78 MiB/s same
Write IOPS, live 60s sample 95/s 151/s zpool iostat -v -l tank 60 2
Write disk_wait 88us 346us to 593us same
Write total_wait 92us 1ms to 2ms same
Lifetime written 76.0 TB n/a smartctl -a /dev/nvme0
Lifetime read 4.16 GB n/a same
Percentage Used 2% n/a same

Read the first two rows together: 42% of the bytes written to tank's data vdevs pass through the ZIL first. That is not an async-dominated workload.

The 76.0 TB written against 4.16 GB read is the signature of a correctly functioning SLOG. It is write-only in normal operation and is read back only during an unclean import, so 4.16 GB over 14,654 power-on hours means the pool has essentially never needed it for recovery. That is the SLOG working, not the SLOG idle.

Why there is sync traffic at all, given sync=standard

sync=standard is set everywhere (local on tank/proxmox_zfs_vms, default elsewhere) and logbias=latency everywhere. Under sync=standard the ZIL only sees writes the client explicitly asks to be durable. Two things are asking, constantly:

  1. SCST advertises a volatile cache. All 68 exported devices report nv_cache = 0 under /sys/kernel/scst_tgt/devices/*/nv_cache, so the target honours SYNCHRONIZE_CACHE and FUA. Every guest fsync (etcd WAL, ext4 journal commits, the *arr SQLite databases) becomes a real ZFS sync write.
  2. Every NFS export is sync. exportfs -v shows sync on /mnt/tank/media, /mnt/tank/isos, /mnt/tank/k8s, /mnt/tank/terraform and /mnt/tank/files.

So ADR 0008 step 3's premise, that tank's workload is "async-dominated", is measurably false while VM disks are still on tank. It becomes true only after they leave, which is why step 3 cannot be justified on its own terms and has to be justified as a consequence of step 2.

What is true about the SLOG

It is absurdly oversized. Peak allocation observed across three samples was 77.5 MiB. At the current 3.70 MiB/s and a 5-second txg window, even a hundred times the observed working set fits in well under 32 GiB. And wear is a non-issue: 76.0 TB is about 3% of the SN850X 4 TB endurance rating, SMART agrees at 2% used, and at the current burn rate (roughly 312 GiB/day) the remaining endurance is on the order of 19 years. The role is worth keeping. Dedicating 3.64 TB to it is not.

Finding 2: the NVMe is 89 GiB too small to protect mirror-3

The obvious cheap mitigation for the mirror-3 problem (both remaining bad-batch drives in one vdev, so one vdev failing loses the pool) is to attach the idle NVMe as a third mirror leg. One command, one resilver, reversible by zpool detach, and mirror-3 would then survive losing both bad drives.

It is physically impossible. zpool attach and zpool replace both require the incoming device to be at least as large as the vdev's asize.

vdev asize (bytes) Members
mirror-0 4,000,780,386,304 WD Blue 24230KD00111, WD Blue 24230KD00129
mirror-1 4,000,780,386,304 WD Blue 24230KD00005, Inland IB24AK0004S00013
mirror-2 4,096,799,539,200 Inland IB24AJ0004S00183, Inland IB24AJ0004S00059
mirror-3 4,096,799,539,200 Inland IB24AK0004S00064, Inland IB24AK0004S00004
SN850X partition 4,000,780,386,304 nvme0n1p1 / nvme1n1p1

The SN850X is 96,019,152,896 bytes (89.4 GiB) smaller than mirror-3's asize. The Inland drives are physically larger than both the WD Blues and the NVMe, and mirror-0/mirror-1 are capped at the WD Blue size.

So the NVMe fits mirror-0 and mirror-1 exactly, and cannot go into mirror-2 or mirror-3 at all. The one vdev where a third leg would prevent pool loss is the one vdev the drive cannot join. Attaching it to mirror-1 instead would protect the third bad drive (IB24AK0004S00013), which is real but not the pool-losing case, at the cost of consuming the drive permanently.

A useful side result: the bad batch is identifiable by serial prefix

smartctl -i reports only Inland SATA SSD as the model for all five. The discriminator is the serial prefix: IB24AK is the bad batch (three drives: S00013 in mirror-1, S00064 and S00004 in mirror-3) and IB24AJ is the good batch (S00183 and S00059, both in mirror-2). This confirms ADR 0008's claim about mirror-3 independently, by serial.

Finding 3: capacity on fast is tighter than ADR 0008 implies

ADR 0008 says the hot data is "about 700 GB on 3.6 TB usable, 19% full, with room to grow several times over". That is true of consumption and misleading about commitment.

Measurement Value
zvols under tank/proxmox_zfs_vms 61
Provisioned (sum of volsize) 2785.1 GiB
Used (sum of used) 663.8 GiB
Referenced (sum of referenced) 506.0 GiB
In snapshots 157.8 GiB across 2233 snapshots
Thin ratio 4.2x

2785.1 GiB provisioned against a 3.64 TiB mirror is 75% committed before a single snapshot, and ZFS write performance degrades past roughly 80%. On tank this overcommit is harmless because 9.66 T is free. On fast it is not.

refquota=4T is set on tank/proxmox_zfs_vms and does not bound the zvols. Verified directly: every child zvol reports AVAIL 9.53T, the whole pool's free space, not the 4.00 T the parent reports. quota is unset. zvol_enforce_quotas is 1, so a real quota will be honoured.

fast must get a quota, not a refquota. ADR 0008 does not mention capacity bounding at all.

Finding 4: tank/k8s cannot ride along with the zvols

ADR 0008 step 2 moves proxmox_zfs_vms (664 G) and k8s (45.9 G) to fast in one step. The second half is a different and much harder change.

The Kubernetes PVCs are provisioned by nfs-subdir-external-provisioner behind StorageClass k8s-nfs, and the dataset path is baked into every PersistentVolume. Verified on pvc-c1e41304-2466-49fa-a8d4-64fdbe5af80d (Loki's 50 Gi volume):

spec:
  nfs:
    path: /mnt/tank/k8s/monitoring/storage-loki-0
    server: 192.168.1.15

spec.nfs.path is immutable on a PV. Moving the dataset to /mnt/fast/k8s invalidates roughly twenty bound PVs, each of which would have to be deleted and recreated with the new path and re-bound by volumeName, plus a Helm values change for the provisioner's NFS_PATH. The failure mode is pods stuck mounting, which is a different blast radius from a zvol move.

Two further points argue for leaving it alone: those PVs target 192.168.1.15, the 1 G LAN interface, not 10.10.12.2 on the 10 G storage network, so NVMe backing is partly wasted behind the transport. And tank/k8s is 45.9 G, so the capacity argument is negligible.

tank/k8s stays on tank. It is a separate decision for a separate ADR.

Candidate uses, evaluated

Option Problem it solves Cost Blast radius Survives one device loss Verdict
A. fast mirror of both, VM zvols only Takes 61 VM disks off a pool whose mirror-3 pairs both bad drives SLOG must be retired first; new PVE storage def; 2233 snapshots lost; needs a quota All VMs in one 2-way mirror, same appliance Yes Recommended, amended as G
B. PBS datastore on the NAS A bigger PBS datastore than 600 G Re-creates a decision already made NAS dies, VM disks and their backups die together Yes (pool), no (appliance) Rejected
C. Mirrored special vdev on tank Accelerates the whole pool without splitting it Adds a third failure domain to a pool that already has a bad vdev; not evacuable Whole pool, and now one more way to lose it Yes (if mirrored) Rejected, better reasons than ADR 0008 gave
D. Keep nvme0 as SLOG, repurpose nvme1 alone Preserves the measured 92us sync path Leaves all 61 VM disks on the bad SATA pool Unchanged, which is the problem n/a Rejected as an end state
E. Single-drive fast, no mirror Can start today without touching the SLOG Every VM disk on one non-redundant device Total lab loss on one NVMe failure No Rejected
F. Do nothing Nothing. Costs nothing. mirror-3 stays a single-vdev pool-loss risk with no alerting (#175) Unchanged n/a Rejected, on narrowed grounds
G. Partition both: 32 GiB SLOG slice + fast mirror on the remainder A, plus keeps the SLOG option alive 64 GiB of 7.3 TiB raw, unused until needed Same as A Yes Recommended
H. nvme1 as a third leg of mirror-3 Would remove the pool-loss risk in one reversible command n/a n/a n/a Impossible. 89.4 GiB too small, Finding 2
I. Re-add a right-sized L2ARC Would serve reads that miss ARC ARC misses are 98.6% satisfied already and metadata misses are 0.008% of metadata reads Low Yes Rejected, settled by ADR 0008 and still true

Notes on the rejections

B, PBS on the NAS. tank/backups (261 GiB of vzdump archives) was deliberately destroyed in terraform-quasarlab#26 because backups must not live on the pool they protect. Putting a PBS datastore on NVMe in a different pool on the same appliance does not change the failure domain that motivated that decision: the NAS is a single appliance and a SPOF, and it also hosts the cluster QDevice and command-center1's cloud-init drive (#199). If the appliance dies, the VM disks and their backups die in the same event. The correct second copy is pbs2, which is already staged as vm120 on pve2 with a 600 G disk on ssd_2 (verified in qm config 120), on different hardware. This is the one option that actively re-litigates a settled decision, and it should not be reopened on capacity grounds.

C, special vdev. ADR 0008 gave two reasons and one of them is wrong. It said a special vdev "is not optional once written: losing it loses the pool, so it inherits the blast radius". A mirrored special survives one device loss exactly as the proposed fast mirror does, so that argument proves too much. It also said 3.6 TB of special for a 5 TB pool is "the same mistake as the current L2ARC in a new hat". That analogy is wrong. The L2ARC's harm was l2_hdr_size, RAM overhead that scales with device size, which is why 3.4 TB of L2ARC ate 20.6 GiB of a 62 GiB ARC. A special vdev has no RAM tax at all. Oversized special is merely wasteful, not harmful.

Reject it anyway, for two reasons ADR 0008 did not have:

  • The read benefit is near zero. demand_metadata_hits is 1,281,629,175 against demand_metadata_misses of 96,646: metadata is served from ARC 99.99% of the time. Misses are overwhelmingly demand data (6,154,391). A metadata special vdev accelerates reads that are already free.
  • To get a real benefit you would need special_small_blocks=16K, which, given volblocksize/recordsize of 16 K on proxmox_zfs_vms, would route essentially all VM data to the special vdev. At that point you have built fast inside tank, keeping the single-pool blast radius and gaining no ability to survive losing tank. That is the opposite of the goal.

D, keep the SLOG and repurpose one drive. This is the option that respects Finding 1, and it is the cheapest. It is still wrong, because the two risks are not comparable. The SLOG is worth roughly 1 ms per sync write. The bad-batch pairing in mirror-3 is worth the entire pool. Option G gets both.

E, single-drive fast. Tempting because nvme1 is free today, so no SLOG retirement is needed and the migration can start immediately. Rejected: it puts every VM disk in the lab on one device with no redundancy for the duration of the migration and the subsequent resilver. PBS with a passed restore drill makes that survivable rather than reckless, but it trades a bounded performance cost for an unbounded data-loss cost. Never trade redundancy for latency.

F, do nothing. More defensible today than on 2026-09-20, and that should be said plainly. tank is ONLINE with zero read, write and checksum errors, "No known data errors", 34% full, 25% fragmented, zero ata link resets in 16 days of uptime, a 99.08% ARC hit rate and a SLOG absorbing sync writes at 92us. There is no performance problem to fix. PBS landing on 2026-10-06 also lowered the cost of the risk materialising. Rejected anyway, but note the narrowed justification: the reason to act is mirror-3, not speed. Any argument for this work that leans on latency is dishonest.

Decision

Adopt option G. The end state is ADR 0008's: a mirror of the two SN850X holding the VM zvols, taking every VM disk off the SATA pool. Three amendments.

  1. Partition both drives up front: a 32 GiB p1 and the remainder as p2. Build fast as a mirror of nvme0n1p2 + nvme1n1p2. Leave both p1 slices unused until measurement says tank needs a log again.

    The reason is mechanical: you cannot carve a partition off a drive that is already a whole-disk vdev member without destroying the pool. Finding 1 proves the SLOG role is real, so the option has to be preserved at creation time or not at all. The cost is 64 GiB of 7.3 TiB raw. The cost of skipping it is redoing the entire migration. ZFS on partitions is already how this box works: boot-pool is nvme2n1p3 and today's SLOG is itself nvme0n1p1, not a whole disk.

  2. Set quota on fast/proxmox_zfs_vms, not refquota. See Finding 3. Suggested value 2.5 T, which bounds the 2785 GiB of thin commitment below the 80% line and still leaves room.

  3. Leave tank/k8s where it is. See Finding 4.

And drop ADR 0008 step 4, the tank rebalance. Do not execute it. The rebalance exists only to stop mirror-3 pairing two bad drives, but the RMA (#193) replaces those drives. Rebalancing now means three resilvers on bad drives, then three more when the replacements land: six instead of three, on drives whose failure trigger is still not established. Worse, a rebalance by detach-and-attach runs a resilver on a vdev that is deliberately degraded, which is precisely the scenario ADR 0008's own consequences section names as "how a pool is lost". A straight zpool replace after the RMA keeps the old drive in the vdev until the resilver completes, and never degrades anything.

Step 4 was the right diagnosis with the wrong remedy. The remedy is the RMA.

Ordering, and why

Full detail in the runbook. The constraints:

Must happen Before Because
0 ZFS pool health alerting (#175) everything Three drives failed and Prometheus stayed silent. Resilvers and topology changes on an appliance with no alerting is how a recoverable event became the 4.5 hour wedge on 2026-09-20
1 pbs1 to pbs2 sync job any topology change Cheapest risk reduction available, pure addition, no lab risk. Roles are already open in ansible-quasarlab#215
2 RMA #193 and zpool replace the rebalance (which is now cancelled) Replacing the bad drives dissolves the mirror-3 problem without a rebalance
3 PVE 9 upgrade and freenas-proxmox 3.0.0 creating the fast storage definition fast needs a new ZFS-over-iSCSI storage definition interpreted by a plugin that is apt-held at 2.4.0-1 (confirmed hi in apt-mark showhold) and known to fail the 8 to 9 dist-upgrade through its dpkg trigger. Defining fast against 2.4.0 means validating the migration twice. Do the plugin work once, then define fast once
4 SLOG removal from tank creating fast The coupling. Both drives are needed for the mirror

Note that steps 2 and 3 have unknown timing and the mirror-3 risk is live in the meantime. There is no clean interim mitigation available: Finding 2 rules out the obvious one on physics. What is available is steps 0 and 1, which convert "the pool might die silently" into "the pool dies loudly and we restore from two independent copies". Do those now, this week, and treat them as the mitigation.

The exposure this creates, stated plainly

Between zpool remove tank <log> and the last VM leaving tank, every guest fsync on tank lands on the SATA mirrors at 346us to 593us disk_wait instead of 88us, and the ZIL stops being a separate device so sync writes contend with data writes. Roughly 4x to 6x worse per sync write. The thing that cares is etcd WAL fsync, whose baseline was already about 74 ms, and 2 of 3 etcd members are on pve2.

The alternative ordering (option E, migrate to a single-device fast first so the SLOG keeps working throughout) removes that regression by removing redundancy instead. Take the latency hit. Mitigate it by migrating the sync-sensitive VMs first: etcd members, then anything with a database. The regression is bounded, measurable, and undone at any moment by zpool add tank log.

zpool remove of a log vdev is not the operation that wedged the lab

On 2026-09-20 a zpool remove of the cache vdev, pitched as "instant and reversible", aggravated an overloaded NAS into a 4.5 hour wedge and a cold power cycle. That removal had 20.6 GiB of l2_hdr_size to tear out of ARC. Removing a log vdev has no ARC work to do at all: it quiesces the ZIL, flushes outstanding sync writes to the data vdevs, and detaches. Mechanically it is a much smaller operation.

That is not permission to run it casually. It is still a pool topology change on an appliance with a demonstrated capacity to wedge under load. "Reversible" and "safe to run right now" are different claims, and ADR 0008 collapsed them. Run it in a window, with alerting live (step 0) and PBS verified (step 1), and with zpool iostat open.

The SLOG question, answered

Yes, the SLOG is earning something today, and it is quantifiable. 49 write IOPS and 3.70 MiB/s sustained over 16 days of uptime, 95 IOPS in a live sample, acknowledged at 92us against 1 ms to 2 ms total_wait on the SATA mirrors. 42% of the bytes reaching tank's data vdevs pass through the ZIL first. Full detail in Finding 1.

What cannot be quantified read-only is the end-to-end user-visible benefit: how much of that 1 ms to 2 ms difference a guest actually observes, after SCST queueing, the 10 G network and QEMU's libiscsi path. Measuring that needs an A/B with the SLOG removed, which is a mutating change and is not done here. Marked unverified. The device-level latency gap is real and measured; the guest-level consequence is inferred.

The honest summary: the role is worth keeping, a 3.64 TB device for it is not, and after the VM disks leave tank the sync load drops to NFS-sync traffic on media, isos and k8s only, at which point a log device may genuinely stop earning its place. That is why recommendation G keeps the option and defers the judgement rather than retiring the role on today's evidence or ADR 0008's.

The ARC question, answered

Yes, cap it. zfs_arc_max = 51539607552 (48 GiB). But this is a guardrail, not a fix, and the case is weaker than it looks.

Measured today:

Metric Value
zfs_arc_max 0 TrueNAS default, not tuned
c_max 66,086,522,880 61.55 GiB of 62 GiB host RAM
c (target) 51,840,468,464 48.28 GiB
size (actual) 50,307,580,376 46.86 GiB
c_min 2,098,758,272 1.95 GiB
memory_available_bytes 6,345,863,552 5.91 GiB
arc_no_grow 0 not currently under pressure
evict_skip 8,161 negligible
Lifetime hit rate 1,718,164,113 / 15,882,958 99.08%

The argument for capping: c_max permits ARC to take 61.55 of 62 GiB, leaving under half a gigabyte for the OS, SCST with its 68 exported devices, nfsd, middlewared, the ix-apps Docker stack and the cluster QDevice VM that runs on this appliance. That only works because ARC shrinks under pressure, and ARC shrinking is reactive and lags the pressure that triggers it.

48 GiB costs nothing measured. ARC has self-tuned to a 48.28 GiB target and a 46.86 GiB actual size, so the cap pins it where it already sits and removes only the headroom to balloon under some future workload. The 99.08% hit rate is the hit rate at this size.

The argument against, which should be recorded rather than buried: the specific RAM pressure that contributed to 2026-09-20 was l2_hdr_size at 20.6 GiB, and it is already gone. l2_hdr_size reads 0 today. So this recommendation does not fix an observed problem. It is a cheap ceiling against a repeat by some other route.

Confidence: high that 48 GiB is harmless, medium that it is necessary. Set it, in Ansible rather than by hand, and do not credit it with anything.

What in ADR 0008 is now stale or wrong

ADR 0008 Status
Step 1, destroy the L2ARC Executed 2026-09-20. Correct call, correct reasoning. l2_hdr_size is now 0
Step 1's "Instant, reversible, no migration" Wrong, and it cost 4.5 hours. The removal wedged an already-loaded NAS and forced a cold power cycle. The claim was true of the command's semantics and false of its behaviour under load. ADR 0008 also calls it "the highest value per unit of risk of anything here", which was right about the value and wrong about the risk
Step 1's predicted "returns 20.6 GiB to ARC" Not delivered as predicted. ARC size is 46.86 GiB today against the 48.2 GiB recorded on 2026-09-20, so it did not grow by 20 GiB. ARC's target had already absorbed the headroom. The hit rate also moved from 99.27% to 99.08%, so the predicted improvement did not appear either. Neither is a problem; both are predictions recorded as outcomes-in-waiting that did not come true
Step 2, create fast and move hot data Right end state, three amendments. Capacity bounding missing (Finding 3), tank/k8s cannot ride along (Finding 4), and the SLOG coupling is unstated
Step 2's "about 700 GB on 3.6 TB usable, 19% full" Misleading. True of consumption, but 2785.1 GiB is provisioned across 61 thin zvols, which is 75% of the mirror before snapshots
Step 3, retire the SLOG Premise refuted. "Async-dominated" is false while VM disks are on tank. See Finding 1
Step 3's "11.5 MiB used of 3.64 TB" as evidence of no utility Category error. Measures allocation, not utility. Near-zero allocation is correct SLOG behaviour
Step 4, rebalance tank mirrors Should be cancelled, not executed. The RMA supersedes it. See Decision
special vdev rejection, reason 1 ("losing it loses the pool") Weak. A mirrored special survives one device loss, same as the proposed fast
special vdev rejection, reason 2 ("the L2ARC mistake in a new hat") Wrong analogy. The L2ARC's harm was RAM headers scaling with device size. A special vdev has no RAM tax
Dataset table: backups 158 G Gone. tank/backups destroyed in terraform-quasarlab#26
Dataset table: media 4.21 T, proxmox_zfs_vms 656 G, k8s 44 G Now 4.27 T, 664 G, 45.9 G. Drift only
"three Inland SSDs pending RMA, two of them paired in the same mirror" Confirmed independently by serial. IB24AK prefix, S00064 and S00004 both in mirror-3

One meta-point. ADR 0008's own Validation section says "Record the results here rather than assuming them" and warns about "a plan recorded as though it were an outcome". Step 1 was then executed and its three predicted outcomes (20.6 GiB returned to ARC, hit rate rises, done in seconds with no disruption) were none of them recorded, and none of them happened as written. The warning was correct and was not followed. That is the strongest argument for keeping the validation table in this ADR short, specific and actually filled in.

Consequences

  • fast becomes a single failure domain for every VM disk. Two-way mirror, survives one device. Not a regression: tank is that failure domain today and contains three drives that drop off the SATA bus. But it is also not an improvement in cardinality, only in component quality (2% worn SN850X, 100% spare, zero media errors).
  • The NAS remains a SPOF and this ADR does not touch that. Same appliance, same QDevice-on-the-NAS problem, same command-center1 cloud-init dependency (#199). Splitting one pool into two reduces the pool blast radius, not the appliance blast radius. Anyone reading this as "the lab now survives the NAS" has misread it.
  • 2233 snapshots holding 157.8 GiB are lost in a PVE Move Disk, which copies current state only. This is acceptable now in a way it was not when ADR 0008 was written: before 2026-10-06 those hourly snapshots were the only recovery mechanism for VM disks, and now PBS is, hourly, with 24/7/4/3 retention and a restore verified against nginx2 (hostname, kernel, root filesystem, package count and /etc md5 all identical). PBS landing is what makes this step affordable.
  • Since 2026-10-15 the PBS cadence in the point above is daily, not hourly (ansible-quasarlab#241), with retention 1/7/4/3 rather than 24/7/4/3. The table and the argument above are left as written, because they record what was true when this decision was taken. The decision does not change: PBS is still the recovery mechanism that makes losing the snapshots affordable. What changes is the number behind "affordable", from an hour of exposure to a day, so step 6 of the runbook now says to trigger a backup by hand immediately before a Move Disk instead of relying on the hourly run.
  • zfs send -R is not an alternative for preserving them. The freenas-proxmox plugin creates the SCST extents through the TrueNAS API, so hand-replicated zvols would arrive with no iSCSI target mapping. Use Move Disk and accept the snapshot loss.
  • A degraded sync-write path on tank for the duration of the migration. Bounded, measurable, reversible. See the exposure.
  • Two pools, two capacity numbers, a second ZFS-over-iSCSI storage definition against a third-party plugin on a distribution that is already EOL. Accepted, and the reason the PVE 9 upgrade is sequenced first.
  • media stays on SSD and tank/k8s stays on SATA. Both unchanged from ADR 0008's position on media, and a deliberate reversal on k8s.
  • No live migration anywhere in this. pve is Intel and pve2 is AMD, so every VM move is shutdown-and-start. Move Disk itself is online, but any step that needs a VM on the other node is not.

Validation

Nothing here is validated. These are measurements and a plan. Record results in this section as they land, and leave the unfilled rows visibly unfilled.

# Claim to test How Result
1 ZFS pool health alerting actually fires Offline a drive in a scratch pool, or zinject, and confirm Discord not done
2 pbs2 holds a complete independent copy Restore one VM from pbs2, not pbs1, to a scratch VMID and diff as the nginx2 drill did not done
3 Removing the SLOG degrades sync writes by the predicted 4x to 6x zpool iostat -v -l tank 60 before and after; record etcd WAL fsync p99 from Prometheus not done
4 fast outperforms tank for VM workloads etcd WAL fsync p99 and Uptime Kuma NFS probe latency, against today's baseline not done
5 The quota on fast/proxmox_zfs_vms is not vacuous Read AVAIL on a child zvol, not the parent. It must report the quota, not the pool free space not done
6 Capping ARC at 48 GiB does not move the hit rate arcstats hits/misses over a week either side not done
7 tank no longer needs a log device After the VMs leave, zpool iostat -v tank log-vdev IOPS should collapse toward NFS-sync traffic only not done

Row 5 is the one most likely to be skipped and is the one that has already caught this lab out once: refquota on the parent reads as a ceiling in the Proxmox UI and bounds nothing.

Confidence, and what could not be verified

High confidence, measured directly and cited above: the SLOG's IOPS, bandwidth, latency and lifetime figures; the 89.4 GiB size shortfall against mirror-3; the drive serial to vdev mapping and the IB24AK/IB24AJ batch split; refquota being vacuous for child zvols; the 2785.1 GiB thin commitment; SCST nv_cache=0; every NFS export being sync; the ARC figures; nvme1n1p1 being a member of no pool; the PV path immutability problem.

Inferred, not measured:

  • The guest-visible benefit of the SLOG. Device-level latency is measured. How much of it a VM sees through SCST, 10 GbE and libiscsi is not. Requires a mutating A/B.
  • Resilver duration for the RMA replacements. The only data point is "13.8 G in 11:05 on 2026-09-16", which is too small to extrapolate from.
  • That PVE 9 plus plugin 3.0.0 will accept a second ZFS-over-iSCSI storage definition cleanly. Taken from upstream ADR-009 and not tested here.
  • Whether tank still wants a log device after the VMs leave. That is validation row 7 and the reason the 32 GiB slices exist.

One premise in the brief that needs a footnote: the uptime was given as "2 weeks 2 days (since 2026-09-20 15:37:46)". uptime on the NAS at 17:39 on 2026-10-07 reports 16 days, 2:01, which puts the boot at roughly 2026-09-21 15:38, one day later than stated. The 16-day figure is right and nothing in this ADR depends on the date, but the 2026-09-20 incident and the NAS boot are not the same moment.